top of page

G-force measurement kit

A 3-axis vibration measurement system with direct PC connection

NECS A16-U3 is a PC-based vibration acceleration measurement system that measures and analyzes vibration in real time.

NECS g-force measurement kit

A simple 5-step measurement process

01

S/W installation & connection

Launch software, connect to PC via USB Type-C, automatic port recognition

02

Calibration

1-Click calibration, takes 6 seconds

03

Real-time monitoring

View X/Y/Z 3-axis vibration graphs

04

Analysis

FFT, filter, resonant frequency, Gpeak, RMS, min, THD analysis

05

Output generation

Save CSV data and generate PDF reports

Components

A16-U3 main unit: Main body and sensor, 1 ea
USB C to C cable: For data communication and power supply, 1 ea
Tape: Special double-sided tape for sensor mounting, 50 ea
USB stick: Executable file for the dedicated analysis program
RMA: Dedicated jig for mounting the NECS RMA to generate actual vibration and conduct measurement tests

Components

Product specifications

항목(Item)
사양(Specification)
Measurement range
± 16 G
Output rate
Up to 1,000 Hz
Resolution
16 bit / 0.01 G
Stability
0.005 G
Interface
USB Type-C connection / COM Port serial communication
Baud rate
921,600 bps
Platform
Windows 10/11
Data storage
Local storage only, no external server transmission
Temperature conditions
-40℃ ~ +85℃
Model name
A16-U3

Ideal for measuring vibration in:

Mobile/wearable haptics

Tactile evaluation of switches, buttons, and input devices

Vibration verification for consumer electronics

Smartphone/wearable vibration motor operation testing

Waveform/FFT-based before-and-after tuning comparison

Response comparison by driving condition

Repeatability/reproducibility verification

Resonant frequency identification of drive units and vibration sources

Residual vibration measurement of product casings

From measurement to analysis to reporting—all with dedicated software

S/W measurement
Main dashboard

Real-time X/Y/Z 3-axis acceleration graphs, port connection status, sensor recognition guidance

Settings & data logging

Sensor bandwidth configuration, real-time CSV saving, Remove DC function

S/W data analysis
FFT analysis

FFT Window, Bandpass Filtering, Analysis Window settings, resonant frequency detection

S/W calibration
Calibration

Attach to a flat surface and complete offset calibration within approximately 6 seconds

S/W CSV data
Measurement data logging file export:

Save timestamp and x/y/z acceleration data

CSV export:

CSV files enable post-analysis and integration with internal tools

PDF report
One-click PDF report generation

Purchase inquiries and resource download

PDF
Product brochure (KR)
bottom of page